CLINIMED Mix & Match

Any tip. Any size. Any hub.

Every CLINIMED cannula is made with the hub that fits your handle, syringe or power system. Spin the reels and see what we can build for you.

59tip styles
13diameters, Ø0.64 – 5.0 mm
7hub systems
1,310configurations in the store today
CLINIMEDReusable · Made to order
Tip
Ø mm
Hub
or use ▲▼ to build your own
+
✓ WE MAKE IT

Configure & order →

Need to use one cannula on several systems? See the Hub & Compatibility Guide for adaptors.

MicroAire®, PAL®, Nouvag®, Liposurg®, VASER®, Vent-X™, Alma® and BeautiFill® are trademarks of their respective owners. CLINIMED is not affiliated with these companies; these products are designed to be compatible with their systems.

How our cannulas are made

Made to a higher standard.

Four details set a CLINIMED cannula apart before it ever reaches the patient: the steel, the finish inside the lumen, the hub you hold, and a handle that comes off.

Electropolished CLINIMED Mercedes Plus cannula tip
The cannula

304 stainless steel, electropolished inside and out

Each tube is first hand-buffed to a No. 8 true mirror finish (Ra ≤ 0.05 µm), then electropolished on the outer surface and inside the lumen to Ra ≤ 0.38 µm (15 µin), the electropolished-finish benchmark used for pharmaceutical process tubing. The result is a smooth, bright finish with no machining burrs or rough spots for tissue and fluid to cling to, so lumens rinse clean faster and are easier to inspect during reprocessing.

304 SSElectropolished OD + IDOD Ra ≤ 0.05 µm · ID Ra ≤ 0.38 µmReusable · autoclavable
CLINIMED anodized aluminium cannula hub
The hub

Medical-grade aluminium, not stainless steel

Traditional hubs are machined from stainless steel. Ours are machined from 6061-T6 medical-grade aluminium and finished to Ra 0.8 µm. That takes weight off the end of the cannula, for less fatigue over a long case and a better feel for the tip, and leaves a fine, smooth surface that is comfortable in the hand and easy to wipe clean.

6061-T6 aluminiumRa 0.8 µm fine finishAnodized colour
66%lighter than the same hub in 316 stainless steel
6061-T6 aluminium1×
316 stainless steel2.96×
Same hub geometry, by material density.
The colour

Colour-coded by diameter

Every hub is anodized in the colour of its cannula diameter, from black NANO (under Ø1.0 mm) through violet MICRO, blue MINI, green MIDI and yellow MAXI to red MACRO (Ø5.0 mm and up). Pick the right size off the tray at a glance, and spot a misplaced cannula before it is handed over.

The 2-part system

One handle. Interchangeable cannulas.

Many liposuction cannulas are sold as one piece, with the handle permanently fixed to the cannula. Every CLINIMED cannula is part of a 2-part system: the cannula threads into a separate handle, and comes off again for cleaning or a change of tip.

CLINIMED universal suction-assisted liposuction handleCLINIMED cannula with ACME hub
Handle · stays on the suction tubingCannula · threads on and off
01
Easier to clean, and cleaner
With the handle off, a brush and rinse water go straight down the lumen from the hub, with no handle channel in the way. That matters most on long cannulas.
02
Fits clinic autoclaves
Long one-piece cannulas can be too long for the tabletop autoclaves found in clinics and alternate-site facilities. Without a fixed handle, our cannulas are shorter to sterilize and fit standard chambers.
03
Change cannulas mid-case
The handle stays connected to the suction tubing and pump the whole time. Unthread one cannula, thread on the next and carry on, with no tubing to disconnect.
04
Lower cost of ownership
One handle serves every cannula with the same hub, so you add tips and sizes as you need them. If a cannula is damaged, you replace the cannula, not the handle as well.
Why the inside matters

Clean inside, by design.

The lumen is where fat, tissue and fluid travel, and where manufacturing residue hides. When vents are cut with traditional milling and drilling, burrs and fine metal particles can be pushed into the tube, where they are hard to see and harder to remove.

We cut every vent and hole on specialty CNC laser cutting machines, so each feature is shaped precisely and identically from one cannula to the next. Each tube is then electropolished inside and out, which dissolves the microscopic edges and residue left by cutting. Finally, every cannula is ultrasonically cleaned and inspected inside with a borescope, from Ø0.64 mm up to Ø5.0 mm.

OUTSIDE
Ra ≤ 0.05 µm
No. 8 mirror, hand-buffed, then electropolished
INSIDE THE LUMEN
Ra ≤ 0.38 µm
Electropolished, every diameter
STEP 1
Specialty CNC laser-cut
Vents and holes shaped precisely and repeatably.
STEP 2
Hand-buffed
Outer surface to a No. 8 mirror.
STEP 3
Electropolished
Inside and out, removing edges and residue.
STEP 4
Ultrasonically cleaned
To flush out any remaining particles.
STEP 5
Borescope inspected
We look inside every lumen before it ships.
Electropolished A. Saad HD cannula tip, close up
A. Saad HD cannula tip · electropolished finish

Hub colour chart

Hub colour shows the cannula diameter, not the hub type.
STOCKED DIAMETERS
0
1.0
2.0
3.0
4.0
5.0
6
Cannula outer diameter, mm
Every size we stock, to scale
Circles drawn 15× actual diameter
0.64
0.9
1.0
1.2
1.5
1.8
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Custom hub colours are available for OEM and private-label customers. Contact us for details.
Spin Mix & MatchHub & Compatibility Guide